Installation
sy
d-
021
0/1.
7
– I7.
9 – 1
2.
2009
4. 5. 5
Component mounting rules
The component mounting rules mentioned in the previous chapters are listed here
in an overview:
•
In principle the interface cards can be used in all the card slots.
Exceptions:
– The AD2 terminal cards EAD4V and EAD4C cannot be fitted to slot IC4 of an
A300 due to their mechanical dimensions.
– If the ODAB options card is used to connect a door intercom, it must be fitted
to slot IC2 (A150) or slot IC4 (A300).
– If the ODAB options card is used to control switch group positions and exter-
nal devices, it must be fitted to slot IC1 (A150) or slot IC1, 2 or 3 (A300).
•
DSP modules are stackable and must always be fitted to slot SM1. Slot SM2 on
the A300 basic system is provided for the system’s future expansions.
•
On the ESST-2 terminal card the jumper must always be fitted in position T (see
•
The LAN switch module uses two neighbouring wiring adapter slots. If LAN
switch modules are fitted, only AD2 terminal cards can still be fitted to the corre-
sponding card slots.
1)
•
The preferred slots for a LAN switch module are slots WA0 and WA1. This means
that there is always at least one slot still available for other interface cards be-
sides AD2.
•
The interfaces are enabled sequentially when the system is started up. The fol-
lowing rules apply:
– The number of interfaces actually enabled is determined in each case by the
system limits (see
). If a limit value is reached, all the
interface cards or all the interfaces of the last card may not be enabled.
– The interfaces are enabled in accordance with their designation, starting with
the lower designations. This means that the terminal interfaces on the main-
board are always enabled before those on the interface cards.
1)
Not allowed in Australia