Connect the mains cable.
•
Connect one end of the mains cable to the main cabinet and the
other end to a grounded mains power point.
Attention :
The iPBX must be powered off when installing
the mains cable.
Never connect network lines while the mains
power cable is unplugged.
•
Power on the iPBX.
•
Before powering on the cabinet, check that all the following tasks
have been performed:
- all line connections are installed,
- all equipment has been connected to a grounded power point.
•
Power on the iPBX:
- or an iPBX with several cabinets, first power on the expansion
cabinet by setting the
“I/O” switch on the power supply module set to “I”.
- Set the “I/O” switch on the main cabinet power supply module to
position “I”.
•
Check the status of the indicators (see Sections 4.6).
•
Check the UCV card's
system and application
software releases using
the AMP.
Refer to the document Aastra Management Portal AXD-AXL-AXS-
AXS12-A5000 Server – Operating Manual.
•
Restore the data of the
old configuration.
•
Refer to the document Aastra Management Portal AXD-AXL-
AXS-AXS12-A5000 Server – Operating Manual.
Table 20:
OPERATION
DETAILS OF THE OPERATION / COMMENTS
Summary of Contents for AXD
Page 16: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 16 01 2011...
Page 20: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 20 01 2011...
Page 22: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 22 01 2011...
Page 26: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 26 01 2011...