Installation and Maintenance Manual - Aastra 5000
AMT/PTD/PBX/0058/4/6/EN
Description et caractéristiques d’un PBX
01/2011
Page
75
3.2.3
Environmental conditions
Applies to the entire iPBX range
ADS 300X power supply module (AXL iPBX)
CHARACTERISTICS
VALUES
Rated voltage
115 V or 230 V
Tolerances
+/- 10%
Frequency
50 or 60 Hz
Power
300 W
Converter (48 V)
+5 V / 13 A and -5 V / 0,5 A
+12 V / 0,5 A and -12 V / 0,25 A
- 48 V / 1,9 A
40 V (ISDN) / 0,7 A
ring 70 V / 0,2 A
25-50 Hz (
symmetrical current
)
External battery (option)
voir § 3.8.7.1
ADS 150X power supply module (AXS/AXS12/AXS6 iPBX)
CHARACTERISTICS
VALUES
Rated voltage
115 V or 230 V
Tolerances
+/- 10%
Frequency
50 or 60 Hz
Power
150 W
Converter (48 V)
+5 V / 7 A
and
-5 V / 0,1 A
+12 V / 0,15 A
and
-12 V / 0,55 A
- 48 V / 0,45 A
ring
70 V - 25-50 Hz / 0,06 A (symmetrical current)
Batterie externe (option)
voir § 3.8.7.1
PARAMETERS
IN OPERATION
IN STORAGE
Temperature
5 to 40
-10° to 70°C
relative humidity
10% to 80 %, without condensation
10% to 95 %, without condensation