Page 144
01/2007
AMT/PTD/PBX/0020/2/4/EN
7.4.2
Wiring examples
Series wiring in Simplex mode
Figure 7-8: Multi-site synchronization with UCT-L/UCT-S in Simplex mode (series wiring)
Series wiring in Duplex mode
Figure 7-9: Multi-site synchronization with UCT-L/UCT-S in Duplex mode (series wiring)
The two "Master" PBXs are connected via their primary port. The "Slave" PBXs are connected in
series from the secondary ports of the "Master" PBXs.
P
S
ADS300
P
S
ADS300
Maître Prioritaire
Esclave
P
S
ADS300
Esclave
P
S
ADS300
P
S
ADS300
Esclave
Esclave
L1
L2
L3
L4
Slave
Slave
Slave
Slave
Priority Master
P
S
P
S
P
S
P
S
P
S
Esclave
Esclave
Esclave
Esclave
Maître
Prioritaire
Maître
Non prioritaire
P
S
Slave
Slave
Slave
Slave
Priority
master
Not priority
master
Summary of Contents for NeXspan C
Page 2: ...Page 2 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 20: ...Page 20 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 66: ...Page 66 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 70: ...Page 70 01 2007 AMT PTD PBX 0020 2 4 EN Figure 4 2 Bottom view of the LD4 ST card...
Page 134: ...Page 134 01 2007 AMT PTD PBX 0020 2 4 EN...