4.5
(Factory) configuration of the LD4NX ST card with Stocko
format
Figure 4-7: Top view of the LD4NX ST card
There are two operating modes on the LD4NX ST card:
•
LD4N operating mode : standard LD4N configuration (operating mode compatible with the
previous LD4 card).
•
LD4X operating mode, only compatible as of release R4.1 : LD4X operating mode is obtained
by removing or plugging the jumper J14 into pins 1 and 2 and is used to implement following
additionnal functions:
•
the LD4NX ST card in LD4X mode uses the junction assigned to its slot, there are no
more restrictions concerning card installation rules,
•
hardware information of the card can be displayed by MMC (an EEPROM is installed on
the LD4NX ST card in LD4X mode),
•
you can declare up to 10 LD4NX ST cards in LD4X mode on a NeXspan L,
•
the remote power supply status of LD4NX ST card S0 accesses in LD4X mode can be
displayed as soon as the card is in service.
J6
J5
J3
J1
1
4
J10
1
4
J9
1
4
J8
1
4
J7
J2
J4
1
2
1 6
5 10
RUN
DISA
J2-1
J2-4
J2-3
J2-2
J1-1
J1-2
J1-3
J1-4
SW6
SW5
ON
CA1 HVAL
1 2
CA1.1 = ON HVAL
CA1.1 = OFF H not validated
CA1.2 = not wired
J14
J11
J14
1 2 3
CA1 HVAL
Summary of Contents for NeXspan C
Page 2: ...Page 2 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 20: ...Page 20 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 66: ...Page 66 01 2007 AMT PTD PBX 0020 2 4 EN...
Page 70: ...Page 70 01 2007 AMT PTD PBX 0020 2 4 EN Figure 4 2 Bottom view of the LD4 ST card...
Page 134: ...Page 134 01 2007 AMT PTD PBX 0020 2 4 EN...