Troubleshooting Parameters
A-108
41-001129-00 Rev 09, Release 1.4.1
IP Phone Administrator Guide
Appendix A
Parameter
–
log level
Log Level
(in Web UI)
Aastra Web UI
Advanced Settings->Troubleshooting
Configuration Files
aastra.cfg, <mac>.cfg
Description
Specifies the severity level of the logs to be reported to a log file. When
this parameter is set to a specific value, only the logs with characteristics
of this value and higher are reported to the log file.
For example, if this parameter was set to “
Info
”, all logs with a severity of
Info
and higher are reported to the log file (debug entries are dropped).
Changes to this parameter require a reboot of the IP Phone.
Log levels are:
Debug
- All logs are reported to the log file.
Info
- Informational logs and higher are reported to the log file (debug
logs are dropped).
Warn
- Warning logs and higher are reported to the log file (info and
debug logs are dropped).
Error
- Error logs and higher are reported to the log file (warning, info,
and debug logs are dropped).
Fatal
- Fatal errors only are reported to the log file.
Format
Not Applicable
Default Value
0 (Debug)
Range
Aastra Web UI:
Debug
Info
Warn
Error
Fatal
Configuration files:
0 (Debug)
1 (Info)
2 (Warn)
3 (Error)
4 (Fatal)
Example
log level: 3
Summary of Contents for SIP 480i
Page 1: ...Administrator Guide Release 1 4 1 SIP IP PHONE 480i 480i CT 9112i 9133i 41 001129 00 Rev 09...
Page 4: ......
Page 16: ......
Page 34: ......
Page 264: ......
Page 274: ......
Page 290: ......
Page 408: ......
Page 412: ......
Page 462: ......
Page 466: ......
Page 470: ......
Page 502: ......
Page 503: ......