6.1
Interface card
LDS/LDT cards, possibly fitted with one or two ADPCM32 (LDS) and ADPCM32B (LDT)
daughter cards are used to connect DECT base stations to a NeXspan 50.
LDS/LDT cards have T0/S0 interfaces for managing 2- or 4-channel DECT base stations. There
are two versions of each card:
•
LDSA/LDTA: 8 T0/S0 interfaces
•
LDSB/LDTB: 16 T0/S0 interfaces
LDSA/LDTA cards allow sixteen 2-channel DECT base stations to be connected, and LDSB/
LDTB cards eight 2-channel DECT base stations. 4-channel base stations can be connected by
adding one or two daughter cards: ADPCM32 (on LDS) and ADPCM32B (on LDT). An
ADPCM32/ADPCM32B card can manage eight 4-channel base stations.
Note:
The minimum technical state of the LDS card required to support an ADPCM32 card is:
HJ4094xN02
6.2
Configuring the LDS card
6.2.1 References and equipment
Table1: References and equipment
Description
Reference
LDSA
16 T0/S0 interfaces for 2- or 4-channel DECT base stations
HJ4094A
LDSB
8 T0/S0 interfaces for 2- or 4-channel DECT base stations
HJ4094B
ADPCM32
Daughter card for managing 8 x 4-channel DECT base
stations
HJ4402A
AVADQ
Synchronous bus link plug
HR5124B
AVLDT
Synchronous bus link plug
HR5124C
PLDS
40V/48V remote power supply card
HJ4206A
LDSA cable
LDSA-distribution frame link cable
HG4302A
LDSB cable
LDSA-distribution frame link cable
HG4302B
Summary of Contents for X Series
Page 3: ......
Page 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Page 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Page 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Page 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Page 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Page 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Page 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Page 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...