AMT/PTD/TR/0020/2/7/EN
10/2008
Page 13-210
Chapter 13- Multi-site programming
(before R5.1)
Note:
The use of the DECT system in a heterogeneous environment (R4.2 and/or earlier) with
Aastra X series R5.1 sites is not handled in this chapter.
13.1 Precautions to be taken in a multisite configuration
13.1.1 Contiguous multi-site configuration
For practical and operational reasons, it is essential to declare different cell numbers in the
various sites (by allocating a range of numbers to each site). This is because in a multi-site
configuration two neighbouring cells cannot have the same cell number and thus the same base
station number.
The following MMCs must be carried out:
•
Declare the same PARI on all the sites.
•
Same RANDOM registration number on all the sites.
•
Same RS registration number on all the sites.
•
Same MOBILE registration password on all the sites.
Example of MMCs for a contiguous multi-site configuration:
Creating a three-site configuration with three cells each.
•
Site1
•
Cell 00 associated with trunk group 0 Base stations 00 to 07
•
Cell 01
1
08 to 0F
•
Cell 02
2
10 to 17
•
Site 2
•
Cell 10 associated with trunk group 0 Base stations 18 to 1F
•
Cell 11
1
20 to 27
•
Cell 12
2
28 to 2F
•
Site 3
•
Cell 20 associated with trunk group 0 Base stations 30 to 37
•
Cell 21
1
38 to 3F
•
Cell 22
2
40 to 47
It is not necessary to give the trunk groups different numbers in the different sites: the trunk
group represents the resources in the cell of each site.
Summary of Contents for X Series
Page 3: ......
Page 11: ...Page 1 11 10 2008 AMT PTD TR 0020 2 7 FR...
Page 63: ...Page 2 63 10 2008 AMT PTD TR 0020 2 7 EN...
Page 73: ...Page 3 73 10 2008 AMT PTD TR 0020 2 7 EN...
Page 77: ...Page 4 77 10 2008 AMT PTD TR 0020 2 7 EN Figure 4 2 Top view of the LD4 ST card...
Page 103: ...Page 4 103 10 2008 AMT PTD TR 0020 2 7 EN...
Page 105: ...Page 5 105 10 2008 AMT PTD TR 0020 2 7 EN...
Page 129: ...Page 6 129 10 2008 AMT PTD TR 0020 2 7 EN...
Page 171: ...Page 8 171 10 2008 AMT PTD TR 0020 2 7 EN...