START
-
UP AND INITIAL TERMINAL CONFIGURATION
2. START
-
UP AND INITIAL TERMINAL CONFIGURATION
CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches
the temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short
-
circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
2.1. Description of connectors
When connecting access control devices such as a card reader or controller with the Wiegand
connector, you must first switched Wiegand mode to input or output mode.
The RS 485 interface of this device supports access to the access control security module. After the
security module is enabled, the exit button and the lock control will be inactive.
CAUTION!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate
surge protectors is advised. Any damages resulting from surges are not eligible for service
repairs.
12VDC(+)
GND(
-
)
Schema of 12 VDC power supply connector
Alarm outputs
Lock interface
RS
-
485
Alarm inputs
Wiegand interface
Exit
Button
interface
12V
PE
GND
IN1
GND
IN2
GND
COM1
NO1
COM2
NO2
D+
D
-
D0
D1
GND
NC3
COM3
NO3
Przycisk
GND
Router
Or
Switch
Internet
Exit Button
Power
Power
Power
+12V
Earth
GND
Alarm Input Device
Alarm Input Device
Alarm Output Device
Alarm Output Device
RS485+
RS485
-
Access Control Security Module
D0
D1
GND
Pow
er
Card
Reader