17
2. Check that the generator is properly
grounded (Refer to “Ground the
Generator”).
3. Check the oil and fuel levels.
4. Turn the ECS switch (Black) to “
OFF
”
position.
5. Turn the engine switch (Red) to “
OFF
”
position.
6. Pull the choke knob fully out.
WARNING:
The choke is not
required to start a warm engine. Press the
choke knob full in.
7. Turn the fuel cock knob to “
ON
”
position.
8. Pull slowly on the recoil starter until it is
engaged, then pull it briskly.
NOTE:
Grasp the carrying handle firmly
to prevent the generator from falling
over when pulling the recoil starter.
9. After the engine starts, warm up the
engine until the engine does not stop.
when press the choke knob full in.
10. Push the choke knob fully in.
11. Allow the generator to run for several
minutes before attempting to connect
any electrical devices. This allows the
generator to stabilize its speed and
temperature.
NOTE:
When starting the engine in areas where
the ambient temperature is below 0°C
(32°F), the engine automatically operates
at the rated r/min (2800 r/min) for 5
minutes to warm up the engine regardless
of the economy control switch position.
The economy control unit operates
normally afterwards if the economy
control switch is turned to “ON” position.
• In ambient temperature below
0
℃(32℉ ), the engine will run at the rated
speed (2800r/min) for 5 minutes to warm
up the engine.
• In ambient temperature below
5
℃(41℉ )
, the engine will run at the
speed (2800r/min) for 3 minutes to warm