24
The overload indicator light (Red) comes
on when an overload of a connected
electrical device is detected, the inverter
control unit overheats, or the AC output
voltage rises. Then,
the electronic
breaker will activate, stopping power
generation in order to protect the
generator and any connected electric
devices.
The AC pilot light (green) will
go off and the overload indicator light
(red) will stay on, but the engine will
not stop running.
When the overload
indicator light (Red) comes on and power
generation stops,proceed as follows:
1. Turn
off
any connected electric devices
and stop the engine.
2.
Reduce the total wattage of
connected electric devices within the
application range.
3.
Check for blockages in the cooling air
inlet and around the control unit. If
any blockages are found, remove it.
4. Check the AC overload protector.
When it turns off, press to reset it.
Otherwise, it’s not necessary to reset
it.
5. After checking, restart the engine.
NOTE
:
The generator AC output
automatically resets when the engine
is stopped and then restarted.
The overload indicator light
(Red)
may
come on for a few seconds at first
when using electric devices that
require a large starting current, such
as a compressor or a submergible
pump. However, this is not a
malfunction.
The ECS switch (Black) must be turned to
“
OFF
” to increase engine speed to rated
rpm. If the generator is connected to
multiple loads or electricity consumers,
please remember to first connect the
one with the highest starting current,
and last connect the one with the lowest
starting current.
12V DC OUTLET
The 12V DC outlet can be used with the
supplied charge cable and USB charger
and other commercially available 12V
DC automotive style plugs. The DC
output is unregulated and can damage
some products. Confirm your accessory
input voltage is at 12V DC. When using
the DC outlet turn the Economy Control
Switch to the “OFF” position.
WARNING:
Do not operate a
device while it is plugged in to the 12V
DC.
Battery charging
CAUTION
Be sure the battery leads are
properly connected
Be sure the breather hose is properly
connected and is not damaged or
obstructed.
At full charge, electrolyte specific
gravity is between 1.26 and 1.28.
Check specific gravity hourly.
Never smoke or make and break