26
battery charging. Beforing restarting to
charge the battery, press to resetthe DC
protector. If the DC protector turns off
again, stop charging the battery
immediately and consult our service
center.
5. Disconnect the plug from the receptacle,
and remove the charge lead after fully
charged.
MAINTENANCE
Regular maintenance is most important for best performance and safe operation.
WARNING:
Stop the engine
before starting maintenance
work.
Proper routine maintenance of the generator will help prolong the life of the
machine and trouble-free, as well as eco-friendly.
If there are any questions about the maintenance procedures listed in this manual,
please call our service center.
Recommended maintenance schedule as below.
Items Frequency
Pre-Op-
eration
check
(daily)
First 8
hours Every
25
hours
Every 3
months
or 50
hours
Every 6
months
or 100
hours
Every
year As
neces-
sary
Engine oil
Check-level
√
Replace
√
√*
√
√*
Air filter
Check/Clean/Replace
√
√
√*
Spark plug Check/clean/Adjust
gap
√
√*
Fuel tank &
fuel filter**
Check-refill
√
√*
Clean
√
Fuel line
Check fuel hose for
crack or damage
√
√*
Choke
knob
Check choke operation
√
Valve
clearance*
*
Check-adjust
When engine is cold
√
Decarboniz More frequently
√*
Summary of Contents for A112003
Page 37: ...37 WIRING DIAGRAM...