36
Blue smoke
in exhaust
Generator inclined, oil
entered combustion
Move generator to a level position
Too much oil was added to
the crankcase.
Drain excessive oil.
Generator
runs but
does not
support all
electrical
devices
connected.
Bad connecting wires/cables. If using an extension cord, try a different one.
Bad electrical device
connected to generator.
Try connecting a different device
Generator is overloaded,
Overload light is on
Perform these steps: 1. Turn
off
all electrical
devices. 2. Unplug all electrical devices. 3. Shut
down the engine. 4. Wait several minutes and
then start the engine. 5. Try connecting fewer
electrical loads to the generator.
Short in one of the
connected devices.
Try disconnecting any faulty or short-circuited
electrical loads.
Generator
does not
produce
power
Safety device (DC protector)
to “
OFF
”
Press the DC protector to “
ON
”
The AC pilot light (Green)
go
off
Stop the engine, then restart