19
above) on the oil level window.
3.
To add oil:
a)
Remove the Oil Breather Plug.
b)
Using a funnel to avoid spills, pour
enough oil into the Pump Crankcase
to reach the “full” level in the Oil
Level Window.
c)
Replace the Oil Breather Plug.
Cold Weather Operation
Premium quality 30-weight,
non-detergent air compressor oil (not
provided) is recommended for use
with this compressor. Start
compressor in heated area if outdoor
temperatures drop below 32° F. If this
is not practical, drain out the old pump
oil and use SAE 10W Non-detergent Air
Compressor Oil in the pump crankcase
instead whenever the compressor’s
temperature will fall below 40°F. Do
not use multi-viscosity oil (such as
10W-30), they leave carbon deposits
on pump components and lead to
accelerated failure. Heavy operation
may require heavier viscosity oil.
4.
If uncertain which oil to use for this
compressor, please call our customer
service center for assistance.
5.
Change the compressor oil after
the first hour of use to remove any
debris.
CAUTION! TO PREVENT
INJURY FROM BURNS:
Do not
add or change the oil while the
compressor is in operation.
Allow the compressor to cool before
replacing oil.
Check Before Each Starting
Before operating the air compressor,
please check the following carefully:
1.
Check the oil level before operation.
(See “Checking the Oil” section
above)
2.
Check to see that nuts and bolts
are all snug.
3.
If the intake filters are dirty, they
should be replaced or cleaned. Check
unit for any damage.
WARNING:
EXTRA CARE
SHOULD BE TAKEN TO AVOID
PERSONAL INJURIES WITH
AUTOMATICALLY CONTROLLED
COMPRESSORS
WARNING:
Risk of unsafe
operation. Firmly grasp air hose in
hand when installing or disconnecting
to prevent hose whip.
WARNING:
Risk of unsafe
operation. Do not use damaged or
worn accessories.
NOTE: The hose or accessory will
require a quick connect plug if the air
outlet is equipped with a quick
connect body.
WARNING:
Risk of Bursting.
Too much air pressure causes a
hazardous risk of bursting. Check the
manufacturer's maximum pressure
rating for air tools and accessories.
The regulator outlet pressure must
Summary of Contents for A12103