39
Fig 59. TCP Server mode in link mode
Note: Enable Virtual COM mode if the remote site PC’s “Serial to IP” tool is installed.
5.4.2. TCP Client for Link Mode
Operation: [Main]
[4 Serial Settings]
[1 Link mode]
[2 TCP Client]
User can configure STW-602C to work in TCP Client mode. On destination IP & port (default:
COM1:4660/COM2:4661), Enter the desired destination IP and port (Server IP and port) that STW-602C
want to connect to (For example, another STW-602C, or PC for data-collection). The STW-602C can
support two destination host computers simultaneously.
Fig. 60
is the
TCP Client
page.
Fig 60. TCP Client mode in link mode
5.4.3. UDP for Link Mode
Operation: [Main]
[4 Serial Settings]
[1 Link mode]
[3 UDP]
STW-602C can be configured to work in UDP mode to establish connection using
Unicast
or
Multicas
t
protocol. Data can be transmitted from one or multiple serial devices to/from one or multiple host PCs and
vice versa. For example, the original RS-422/ RS485 bus data is transferred over the extended connected
distance by STW-602Cs, The destination IP is assigned by single IP or group IPs, The configuration is
limited by the Local Listening Port, default 4660 and 4661 on the COM1 and COM2 of STW-602C.
STW-602C can support up to 4-group IPs for UDP connection, if users needed.