Chapter 5
Inputs, Outputs and Switch Settings
5-3
Terminal Block - TB3 (A Quad B Board)
Figure 5.1 provides interconnect information between the position
controller and TB3 on the A Quad B Board.
ATTENTION: To guard against possible damage to the A
Quad B Board, assure that wiring between TB3 and the position
controller is correct. Refer to Figure 5.1.
!
Figure 5.1
A Quad B Board Wiring
Important: Note terminal orientation prior to wiring.
1
TB2
20
1
TB3
10
1
Recommended Wire – Belden #9728 or equivalent. Maximum distance between the A Quad B Board and
the position controller is 40 feet (12.2 meters) using a 5 volt signal. For distances up to 300 feet (91 meters),
18 AWG (0.8 mm
2
) wire (Belden 9388 or equivalent) and an 8 to 15V DC power supply must be used.
2
For proper operation when interconnecting to IMC classic products (IMC 110, 12x), the B and B (NOT)
signals must be reversed.
3
When interfacing to IMC 121 or 123 controllers, use the 1391-CAQB cable. When interfacing to the
integrated packages of the MAX or S Class controls, use the 1391-SAQB or 1391 SAQBK cable.
TB3
Number
1
2
3
4
5
6
7
8
9
10
Description
A
A (NOT)
B
2
B (NOT)
2
Z
Z (NOT)
+5V DC (
±
5%)
Signal Common
+8 to +15V DC In
No Connection
A Quad B Board
To Position
Controller
1
Power Supply
Input
1
9
8
7
6
5
4
3
2
1
2
1
S1
Top Logic Control Board
The A Quad B option operates in the same manner as the Allen-Bradley
845H Line Driver Encoder (26LS31 line driver output). The option
requires either a reg5V DC at terminal 7 or an unreg8 to
+15V DC input at terminal 9 (board draws 125mA maximum). The pulse
train output is selectable to 256, 512, 1024 or 2048 lines per revolution via
the Encoder Output switch, S1 (see page 5-6).
Terminal Block - TB4
Please note that there are no connections to TB4-20 & 22.
Contactor Coil (TB4, Terminals 11, 12)
Connections to the coil of the integral contactor are performed at these
terminals. The coil voltage is 115V AC, 50/60 Hz.
Important: Drives with a catalog number of 1391-DESxx-DI-AQB-A will
have a 24V DC coil. Drives with a catalog number of 1391-DESxx-DI-
AQB-B will have a 240V AC coil.
Summary of Contents for ALLEN-BRADLEY 1391-DES
Page 1: ...User Manual 1391 DES Digital AC Servo Drive...
Page 9: ...Chapter 1 Introduction 1 10 End of Chapter...
Page 37: ...Chapter 5 Inputs Outputs and Switch Settings 5 8 End of Chapter...
Page 84: ...Chapter 8 Start Up 8 16 End of Chapter...
Page 88: ...Chapter 9 1326 AC Servomotors 9 4 End of Chapter...
Page 106: ...Chapter 11 Troubleshooting 11 12 End of Chapter...
Page 122: ...Appendix B Interconnect Drawings B 12 End of Appendix...
Page 126: ...Appendix C Cable Information C 4 End of Appendix...
Page 134: ...Appendix E Parameter Record E 8 End of Appendix...
Page 135: ...Notes...
Page 136: ...Notes...
Page 137: ...Notes...
Page 138: ...Notes...
Page 139: ...Notes...
Page 140: ...Notes...
Page 141: ...Notes...
Page 142: ...Notes...
Page 143: ...Notes...
Page 144: ...Notes...
Page 147: ...IMC is a trademark of Allen Bradley Company Inc...