P. 26 - Chap. 4 Performance and specifications
G
B
Model
Pressure
Power cable
cross-section area
Main fuses AM
(motor rated) or ground
circuit breaker setting
Circuit breaker
bar
mm
2
A
A
5.5
8
2.5
16
16
10
13
15
7.5
8
4
20
20
10
13
15
11
8
6
25
25
10
13
15
15
8
10
40
40
10
13
15
15
8
10
40
40
10
13
15
400 V
Model
Pressure
Power cable
cross-section area
Main fuses AM
(motor rated) or ground
circuit breaker setting
Circuit breaker
bar
mm
2
A
A
5.5
8
6
25
25
10
13
15
7.5
8
10
40
40
10
13
15
11
8
16
50
50
10
13
15
15
8
25
63
63
10
13
15
15
8
25
63
63
10
13
15
230 V
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...