P. 27 - Chap. 4 Performance and specifications
G
B
4.7
Lubricated and cooling fluid
The compressor is filled with
DICREA 46
lubricated and cooling fluid
Total capacity:
7 Kg
Top up with lubricated and cooling fluid with the
same specifications as the
lubricated and cooling fluid
in
the machine (synthetic coolant I.E. ABAC DURALUBE may be specified)
Contact the Manufacturer’s technical Department before using
lubricated and cooling fluids
with other
specifications
4.8
Dryer
Thermostat controlled cooling cycle, direct expansion, with Freon R134a gas; pressure dew point
temperature 3°C, clean air filtering degree 0,01mm.
Filtration degree: 1
µ
m.
Oil carryover:
0,1 mg/m
3
Displayable dew point temperature
Cooling compressor and timed condensate drain, controlled from mc panel
2
4.9
Clearance requirements and system layouts
The tables with the overall dimensions of the compressor are provided in
figures 1-12
The hydraulic/pneumatic system diagram and the wiring diagrams (operation and location) are shown in
Chapter 12