P. 59 - Chap. 7 Start-up and operation
G
B
Messages of this type are as follows:
-
Replace air filter
-
Replace oil filter
-
Replace oil
-
Replace separator filter
-
Replace air filter - excess. clogging
for this last fault, after replacing the filter, press the
K3 - RESET
key
2)
For
critical operating condition
messages:
If possible eliminate the problem; the message will be cleared automatically
Messages of this type are as follows:
-
Compression temp. high
-
Ambient temperature low
WARNING!!!
If the warnings are not reset for a long period of time (e.g. failure to carry out scheduled
maintenance) THE COMPRESSOR IS BLOCKED!!! In this case, contact the Service or
Customer Centre of the Manufacturer immediately.
Alarm messages
These messages indicate a serious fault that has blocked the compressor. The alarm may be due to a
fault in the system or extremely critical operating conditions.
When a machine stoppage occurs, the compressor stops immediately, the
red LED L3
of the alarms
switches on and the message relating to the fault is displayed persistently in the main screen page.
To
RESET
, first of all eliminate the fault: at this point,
LED L3
starts to flash indicating that reset
can be carried out pressing the
RESET
key.
All faults that cause blocking of the compressor are saved in an
error message log file
. To consult this log,
refer to paragraph
7.4.2.7
The following faults block the machine:
- EMERGENCY STOP compress. - block
-
Compression temp. too high - block
- Ambient temperature too low - block
- Internal pressure too high - block
- Net pressure too high - block
- Press Transducer error - block
- Temperature sensor error - block
- Power supply phase sequence error - block
- Short-cir. analog INPUT - block
- Compress. motor overload - block
- No. starts/hr too high - block
- Power supply failure - block
- Line voltage cutoff - block
Faults caused by failure to carry out maintenance must also be added to these: if the compressor is used for
long periods without carrying out the scheduled maintenance indicated by the control unit, a machine blockage
occurs accompanied by a message of the type:
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...