P. 64 - Chap. 9 Troubleshooting
G
B
V-F
V-V
Segnalazione
Possibile causa
Intervento
X
X
Excessive
FA clogging
Replace
FA
(see. par. 10.4)
Belts
slipping
Call
Customer
Service Centre
9.4
The machine is ready for start or is running and the
scheduled maintenance LED is ON
V-F
V-V
Indication
Possible cause
Intervention
X
X
L2
flashing
DI
indicates:
“
Replace air filter
excess. clogging
”
FA
clogged
Replace
FA
(see. par. 10.4)
X
X
L2
flashing
DI
indicates:
“
Replace air filter
XXX excess hours
”
FA
to be replaced for
scheduled maintenance
Replace
FA
(see. par. 10.4)
X
X
L2
flashing
DI
indicates:
“
Replace oil filter
XXX excess hours
”
FO
to be replaced for
scheduled maintenance
Replace
FO
(see. par. 10.6)
X
X
L2
flashing
DI
indicates:
“
Replace oil
XXX excess hours
”
Oil
to be replaced for
scheduled maintenance
Replace
oil
(see. par. 10.5)
X
X
L2
flashing
DI
indicates:
“
Replace oil separator
XXX excess hours
”
FD
to be replaced for
scheduled maintenance
Replace
FD
(see. par. 10.6)
X
X
L2
flashing
DI
indicates:
“
Replace dryer filter
XXX excess hours
”
Dryer filters
to be replaced for
scheduled maintenance
Call
Customer
Service Centre
9.5
The machine is ready for start or is running with
critical functioning message
V-F
V-V
Indication
Possible cause
Intervention
X
X
L2
flashing
DI
indicates:
“
Ambient
temperature low
”
Ambient temperature
low
Heat ambient
X
X
L2
flashing
DI
indicates:
“
Compression temp.
High.
”
Oil cooling
low
Check functioning of the
electric fan and its fuses
FU3
.
Call
Customer
Service Centre
Oil radiator dirty
Call
Customer
Service Centre
Oil low
Top up or change oil
(see. par. 10.5)
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...