P. 77 - Chap. 10 Maintenance
G
B
Remove the front panel
PF
with the key
provided
Connect fitting
R
provided, which must
communicate with a suitable collection
recipient, to fitting
DO
after unscrewing
the safety plug (
Fig. 48
)
Partially open drain valve
RSO
(
Fig.
48
)
Follow the operation and close oil drain
valve RSO as soon as oil starts flowing
out
Check the oil level and top up, if
required, as described in the paragraph
“
Checking the level and topping up
”
Replace the safety plug and the PF
panel
Fig. 48
SA
RSC
DO
RSO
The air receiver and separator condensate should be drained manually on a weekly basis - or more
frequently. The user is responsible for this maintenance operation.
Replacing the fuses
10.8
Before performing any maintenance operations read the operator safety precautions in
chapter 5 carefully. These precautions must be followed scrupulously for all maintenance
operations
GENESIS - FORMULA:
Open the corner panel
SPA
of the com-
pressor cabinet using the key provided
MODULO:
Open the electric box panel
SCE
using
the key provided
Replace the damaged fuses. Follow
the amperage specifications provided
in paragraphs 12.8, 12.9
GENESIS - FORMULA:
Close the corner panel
SPA
MODULO:
Close the electric box panel
SCE
Fig. 49
R
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...