background image

- Loosen turn-knob (anticlockwise direction).

- Move suction cup follow to requirement place, tighten turn-knob 

(clockwise direction)

21

Summary of Contents for AVL480

Page 1: ...INES USA 14508 S Garfield Ave Paramount CA 90723 USA Tel 310 532 0366 Fax 310 532 0499 Email sales abacomachines com Website www abacomachines com ABACO MACHINES OPERATION MANUAL ABACO GLASS VACUUM LIFTER AVL480 ...

Page 2: ......

Page 3: ...ion cups positioning which fit well with various size of glass II STRUCTURE Abaco The Glass Vacuum Lifter consists of a main frame which connected to the suction cups via a joined bar The main frame is attached to the hanging bar via swivel joint Besides the main frame is equipped with an electric box and motor 2 Length A inches mm Width B inches mm Height C inches mm 59 1500 68 1735 12 305 Net we...

Page 4: ...ging 220V Minimum applicable size of glass sheet Battery charge time Pump operational period by Battery non stop 6 hrs 30 min 2 hrs 15 min Maximum lead time to achieve the required vacuum pressure 10 seconds USA International 9 250mm 70 x 39 1800x1000mm Specifications 110V Rotate angle Left 90 Right 90 o o Tilt angle 90 o ...

Page 5: ...III STRUCTURE SPECIFICATIONS 1 Overall 3 ...

Page 6: ...L480 12 Pad 3 1 13 AVL480 13 Air compression clamp 2 14 AVL480 14 Air compression 1 15 AVL480 15 Screw M5x10 14 16 AVL480 16 Pad 4 1 17 AVL480 17 Solenoid box 1 18 AVL480 18 Nut M4 2 19 AVL480 19 Cover 1 1 20 AVL480 20 Screw M6x15 2 21 AVL480 21 Base control panel 1 22 AVL480 22 Allen bolt M6x10 4 23 AVL480 23 Washer Ø6 28 24 AVL480 24 Box electric 1 25 AVL480 25 Handle block 1 26 AVL480 26 Cover ...

Page 7: ...raverse beam right 1 41 AVL480 41 Circlip Ø14 5 42 AVL480 42 Washer Ø14 5 43 AVL480 43 Lever sub assembly 1 44 AVL480 44 Pin 1 45 AVL480 45 Spring tension 1 46 AVL480 46 Blind flange 1 47 AVL480 47 Lock nut M8 1 48 AVL480 48 Crank handle 1 49 AVL480 49 Handle grip 1 50 AVL480 50 Allen bolt M8x60 1 51 AVL480 51 Washer Ø8 1 52 AVL480 52 Allen bolt M8x20 1 53 AVL480 53 Rubber cap 3 1 54 AVL480 54 Loc...

Page 8: ...ng or breaking Ensure the slab surface is clean no sign of any liquid such as water andoil Ensureallthesuctioncupsare carefullycleaned up Inspectallthebuttons levers alarm 2 Operating Instruction A When the glass is positioned in vertical dimension Step 1 Moving the glass vacuum lifter close to the glass Note 11 Adjusting the suction cups position to adapt to the glass size See appendix 3 B Ensure...

Page 9: ... Place the glass vacuum lifter closely to the glass surface Step 3 Press green button to activate attract VACUUM Note Ensure that the glass surface is well attracted by all the suction cups simultaneously 12 ...

Page 10: ...assupand down Do not switch lever to adjust the angle to 90 degree and set the glass inverticaldimension whileattracting Step 6 Press button and remove the glass vacuum RELEASE lifter from the glass Note Ensure that the pressure gauge lowering down to 0 before remove thelifter 13 ...

Page 11: ...rom to 0 8 bar 1 bar Step 4 Starting lifting and moving the glass While the system is in attract mode we can rotate the glass to 90 degree Seeappendix3 C Note Beawarethat the pressure gauge must always showing the indicator from to duringattractingprocess 0 8bar 1bar Donotpress redbutton whileattractingtheglass RELEASE 14 ...

Page 12: ...losed to the glass Note Adjusting the suction cups position to adapt to the glass size See appendix3 B Ensure theglassvacuumlifteris setatthecentreoftheglass 15 Before adjustingthelifter sinclination activateattractingfunction sothatallthesuctioncupsare inhorizontal position SeeAppendix3 A ...

Page 13: ...Step 2 Place the lifter closely to the glass surface Note Make sure that all the suction cups need to be attracting to the glass surface Step 3 Press green button to activate attracting VACUUM 16 ...

Page 14: ...tion from to 0 8 bar 1 bar Step 4 Starting lifting and moving the glass While the system operate we can rotate the glass to 90 degree direction See appendix 3 C Note Be aware that the pressuregauge always showing the indicator from 0 8bar 1bar to during attractingprocess Donotpress redbutton whilesuckthe glass RELEASE 17 ...

Page 15: ...Step 5 Place the glass in desired position Note Operate carefully when the glass up and down 18 ...

Page 16: ...Step 6 Press button and remove the lifter from the RELEASE glass Note Ensure that the pressure gauge lower down to 0 before remove the lifter 19 ...

Page 17: ...3 Appendix A Adjusting the suction cups to horizontal dimension Pull the handgrip lock as shown in the picture and rotate the frame to horizontal dimension 20 ...

Page 18: ... Loosen turn knob anticlockwise direction Move suction cup follow to requirement place tighten turn knob clockwise direction 21 ...

Page 19: ...main frame manipulation Pull the handgrip lock as shown in the picture Next rotate the glass vacuum lifter follow to your requirement Note Pin clock automatically install into hole position for angle adjustment 22 ...

Page 20: ...not followed Damage is due to inadequate maintenance and inspections Damage is due to improper storage and or usage Repairs were performed by the user without our permission Non original spare parts were used V INSPECTION MAINTENANCE Schedule periodic maintenance of the lifter especially the suction cups Reserve expendable and or necessary spare parts for maintenance or repair Check the electrical...

Page 21: ...ables The Company is not responsible for any misuse or abuse of the product after purchase and or caused by negligence from the content ofthismanual In case of failure using the device our Customer Support Department will inform you of the appropriate methods of dealing with your claim and advise you of your nearest approvedservice center EXCLUSIONS Warrantydoes notapply fordamages orfailures caus...

Page 22: ...THIS MANUAL SHALL BE REVISED WITHOUT PRIOR NOTICE FOR IMPROVEMENT PURPOSES DO NOT COPY AND OR QUOTE THE CONTENTS WITHOUT PRIOR WRITTEN CONSENTS OF ABACO MACHINES Copyright Abaco Machines E18 ...