Gemini 2000 Installation Manual v1.3
16
3. The next stage is to remove the base pivot shaft from the
base frame. To remove, unscrew the 1 x M5 round head
allen bolt from the shaft bracket. Remove the spring steel
star washer from the opposite end.
Whilst supporting the scissor frame, slide the shaft out of
the frame.
Note: Notice the nylon washers between the base frame
and scissor frame. Be sure to re-fit these when
reassembling.
Note: When reassembled, a spring steel star lock washer
will require fitting to the opposite end of the base pivot
shaft.(Supplied in the dispatch kit).
4. The tap end of the scissor frame must now be slid towards
the tap end of the bath, whilst also lifting upwards. This will
release the black nylon sliding blocks from the framework,
allowing the scissor frame to be lifted and set aside.
When done correctly, the scissor frame will lift away from the
base frame with all wiring attached.
Remove
6. Base frame removal
The bath base frame can now be removed from the foot
plate assemblies.
1. Starting at one end, whilst supporting the frame, remove
the 4 x M8 allen head bolts from the top of the base
frame.(2 bolt each side of frame).
2. Remove the 2 x M8 allen head bolts form the underside of
the base frame.(1 bolt each side of frame).
3. The base frame will now come free from the foot plate
assembly.
Carefully lower the end of the frame to the ground.
4. Repeat the process for the opposite end of the bath.
Remove
Remove