Bath Panel Fitting and Installation
With the bath now reassembled and ready to be fitted, the bath panels can now be fitted ready
for installation.
Be sure that the bath has been raised to the highest position.
Not doing so will hinder
installation and may lead to potential damage
.
Step 1
Fit the bellow to the underside of the base frame using the 2 x M5
round head allen bolts provided.
Note: plastic inserts in baffle should face end of bath.
Repeat for opposite end of bath.
Step 2
Side wall plumbing:
Take the foot side panel which was previously cut, and position wall side
of foot the where plumbing will exit. The panel should follow the contour of the foot plate.
Position so that the bellow fits correctly in the bellow slot in the panel.
End wall plumbing
: Position either side foot side panel at the tap end of the bath. The panel
should follow the contour of the foot plate. Position so that the bellow fits correctly in the bellow
slot in the panel.
Step 3
Take a bottom end panel (with cut-out if peninsula) and put in
to position next to the foot side panel. Rest bottom edge on
floor. Notice the top hooks resting against the frame.
Lift the panel slightly and press forwards hooking the
panel onto the frame.
Be sure that the lower fastmount fits through the larger
hole in the foot side panel, and lower the panel.
Snap the top fastmount fixing into place by pressing firmly.
Step 4
Repeat steps 2 and 3 for the opposite end of the bath,
but on the same side .
Step 5
Taking a middle end panel (with fastmount on the bottom),
bolt into place using the lower holes on the foot frame
assembly. Do not tighten at this stage!.