Abacus Pisces 069/Info.P 04/14v1a
5
1700 Pre Installation Requirements
PLUMBING
(Where there are existing feeds)
This can be either wall or floor fed. Feeds should be as follows:
22mm hot water inlet; 15mm cold water inlet; 40mm Waste outlet @ 3ltr/Sec. Plumb according to Plumbing
Diagrams.
Feeds should terminate with isolating valves.
Side or End Walls Feeds.
Feed & Waste – These must exit bathroom wall in either shaded area marked A.
Fig 1.
Pipwork should terminate
in either shaded box area paying attention to layout intended for manifold and manifold holes height – 65mm.
See
Fig 2
. Plumbing tails must be fitted with isolating valves.
Floor Feeds
Plumbing to exit floor and terminate in either shaded area in
Fig 1.
Please note layout intended for manifold and
manifold holes height – 65mm. See
Fig 2
. Tails c/w elbow should be left at 65mm height off floor for manifold
connection. Plumbing tails must be fitted with isolating valves.
FIG 1
FIG 2
Minimum distance 25mm - Wall & bath sides.
FIG 3
Typical plumbing layout for Side or end wall
TAP END OF BATH