background image

PAS600_MN-IB 

 

2018.04.20 

 

 

 

 
 
 

HEPA-AIRE

®

 

Portable Air Scrubber

 

PAS600 

 
 
 

 

 
 

Instruction Manual 

 
 

 

Abatement Technologies, Inc. 

 

Abatement Technologies, Inc. 

Georgia, USA 

800-634-9091 

Abatement Technologies Limited 

Ontario, Canada 

905-871-4720 

www.abatement.com

 

Summary of Contents for HEPA-AIRE PAS600

Page 1: ...04 20 HEPA AIRE Portable Air Scrubber PAS600 Instruction Manual Abatement Technologies Inc Abatement Technologies Inc Georgia USA 800 634 9091 Abatement Technologies Limited Ontario Canada 905 871 4720 www abatement com ...

Page 2: ... published by the Occupational Safety and Health Administration Centers for Disease Control and Prevention Environmental Protection Agency American Society of Heating Refrigerating and Air Conditioning Engineers and all other federal state provincial and local regulations TABLE OF CONTENTS Safety Instructions 1 Requirements For Safe Operation 1 Important Safety Instructions 1 General Information 2...

Page 3: ...cal equipment always make sure that the unit is turned OFF prior to connecting the power cord to an electrical outlet or disconnecting it from an electrical outlet Failure to do so will cause arcing and could result in personal injury fire hazards and or damage to the unit Do not disconnect the power cord from supply receptacle while the unit is operating Warning To reduce risk of electrical shock...

Page 4: ...ble of filtering many airborne contaminants An alternate carbon pre filter for capturing low concentrations of odors vapors gases and volatile organic compounds collectively known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Lung damaging particles Low concentrations of OVG Dust Metal fumes Low concentrations of Volatile Orga...

Page 5: ...shment of any more accurate rule of thumb than one s sense of smell Since off gassing of adsorbed OVG can occur when the adsorption capacity of the filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Abatement Tec...

Page 6: ...k to ensure that any circuit to which the unit is connected is protected by a 15 amp circuit breaker The unit itself is equipped with a 12 amp circuit breaker 5 The units should be connected to a three prong properly grounded electrical outlet equipped with a Ground Fault Circuit Interrupt GFCI device A GFCI is an electrical safety device that will trip the circuit and stop the flow of electricity...

Page 7: ...f contaminated air To ensure that the proper pressure differential is maintained the volume of HEPA filtered air exhausted from the containment area must be the greater of 10 or 100 CFM higher than the volume of air entering This pressure differential can be established by a placing the unit inside the containment area and using it to push air out of the containment area Attach flex duct at the ou...

Page 8: ...is 8 amp limit Note If the equipment connected to the GFCI receptacle draws more than a total of 8 amps the circuit breaker on the control panel and or the building breaker will trip This condition can be remedied only by reducing the total amperage draw DAISY CHAINING Daisy Chaining refers to the operation of multiple units on one circuit with only one of the units plugged into a 120 V 15 A elect...

Page 9: ...Technologies cannot recommend the type of PPE required as that will need to be determined by safety risk assessment personnel based on various risk factors including the type of particulates being captured by the air filtration device and the surrounding environment where the units are being used transported or serviced Note Filters being replaced must be disposed of in accordance with federal sta...

Page 10: ...N after changing the first stage filter the second stage filter should be replaced Changing the Second Stage Filter 1 With the unit operating turn the latches on the pre filter access door counter clockwise and open the door 2 Open the pre filter access door 3 Remove the second stage filter by lifting it up until the bottom clears the filter door cavity Tilt the bottom of the pleated filter out an...

Page 11: ...estart motorized impeller that will restart without warning after a temporary power interruption or recovery from a thermal overload over heating condition Keep clear of the motorized impeller at all times to reduce the risk of injury Occasionally a defective component will cause the unit to operate improperly or not at all Any electrical component can fail Refer to the Wiring Diagrams and Wiring ...

Page 12: ...tacked Pre filter access Swing out hinged door secured in place with cam latch First stage pre filter 1 deep coarse particulate pre filter P N F621 Second stage pre filter 2 deep pleated particulate pre filter P N H502 Alternate second stage pre filter 2 deep high capacity carbon filter for odors P N VL1002 HEPA filter HEPA mini pleat filter with continuous seamless gasket tested and certified to ...

Page 13: ...l panel Thermal overload on the motorized impeller has tripped Turn unit OFF wait 30 minutes and restart unit Circuit breaker on control panel or building trips Overloaded circuit Unplug any additional equipment connected to the circuit Reset circuit breaker Filter change indicator is ON Loaded filters Change in accordance with operating instructions Excessive restrictions Reduce bends length of f...

Page 14: ...ifications shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly or indirectly arising from the ...

Page 15: ...13 PAS600 DIAGRAMS ...

Page 16: ...14 ...

Page 17: ...15 ...

Reviews: