FILTER REPLACEMENT 

Note: Personnel responsible for changing filters, servicing units or relocating units within the facility are urged 

to wear the proper personal protective equipment (PPE) and follow safe work practices in accordance with 

federal, state, provincial, local and employer regulations.  Abatement Technologies cannot recommend the 

type of PPE required as that will need to be determined by safety/risk assessment personnel based on various 

risk factors, including the type of particulates being captured by the air filtration device and the surrounding 

environment where the units are being used, transported, or serviced. 

 

Note: Filters being replaced must be disposed of in accordance with federal, state, provincial, local and facility 

regulations. 

 

System airflow reduction is generally the result of filter loading, blockage of the unit’s inlet or use of excessive 

lengths of flex duct that is connected to the inlet. 

 

The size and concentration of airborne contaminants, temperature and humidity conditions, and duration of use 

determine how often filters need replacement. If the Filter Change Indicator on the control panel illuminates, 

this indicates one or more of the following: (1) filter(s) are loaded, (2) the inlet is obstructed, and (3) the flex 

duct, if attached to inlet, is too long or has too many bends. 

 

The method of determining when to replace an activated carbon filter is somewhat subjective. As the odor, 

vapor, and/or gas filtration capacity decreases, the user will begin to sense a slight odor or taste of the 

contaminant, indicating that the filter should be replaced. 

 

Note: The filters are not reusable, therefore, do not attempt to clean and reuse them. 

 

Caution: Abatement Technologies PREDATOR® Portable Air Scrubber units are designed to meet or exceed 

standards for high efficiency air filtration equipment. Use only Abatement Technologies parts, including 

replacement filters. Use of non-Abatement Technologies parts and filters voids the product warranty and all 

performance claims. 

 

Warning: To reduce the risk of fire, electrical shock or personal injury, always turn the unit “OFF” and 

disconnect the power cord from supply receptacle before replacing the HEPA filter and before cleaning or 

servicing the unit. 

 

FILTER CHANGE PROCEDURE 

The filter indicator light located on the control panel will indicate when one or more of the filters need to be 

changed.  This is based on a factory setting and the filters can be changed earlier, if desired, to maintain a 

minimum air flow requirement.  Since the filter indicator light is based on the pressure drop across ALL of the 

filters, it cannot indicate specifically which filter(s) need to be changed.  Therefore, when the light turns on, the 

filters should be changed in a progressive order, starting with the first stage filter, until the indicator light turns 

off.   

 

To Change the First Stage Filter: 

1.

 

With the unit operating, turn the two latches on the pre-filter access door counterclockwise (approx ½ 

turn), swing the latches outward, and open the door.  Remove the first-stage filter located inside the 

door itself and replace it with a new one. 

2.

 

Close the door and lock it in position by swinging the latches inward and turning the latch clockwise. 

Make sure the door is flush against the unit's cabinet before closing the latch. 

3.

 

If the Filter Change Indicator light remains “ON” after changing the first-stage filter, the second stage 

filter should be replaced. 

Summary of Contents for PREDATOR PRED750

Page 1: ...els PRED750 PRED750EC INSTRUCTION MANUAL U S PATENT D742495 CANADIAN PATENT 2852880 Ⓓ ABATEMENT TECHNOLOGIES INC Abatement Technologies Inc Abatement Technologies Inc Georgia USA 800 634 9091 Abatement Technologies Ltd Ontario Canada 905 871 4720 www abatement com ...

Page 2: ... N H502 Alternate Second Stage Filter 2 High Capacity Vapor Lock Carbon Filter P N VL1002 3 Final Stage 99 97 HEPA Filter P N H161606 99 4 HEPA Filter Retaining Brackets 5 Motorized Impeller located inside cabinet 6 Pre filter Access Door 7 Control Panel 8 Carrying Handle 9 Air Intake 10 nominal diameter 10 Exhaust Outlet 10 nominal diameter ...

Page 3: ...ernate carbon pre filter for capturing low concentrations of odors vapors gases and volatile organic compounds collectively known as OVG is also available Types of contaminants captured by particulate pre filters HEPAfilter or carbon filters Dirt Lung damaging particles Low concentrations of OVG Dust Metal fumes Low concentrations of Volatile Organic Compounds VOC Drywall dust Smoke Saw dust Mold ...

Page 4: ...ectiveness by exposing OVG particles to multiple passes through the Vapor Lock filter It is almost impossible to provide accurate estimates to two commonly asked questions how much time will it take to capture all of the OVG and how do I know when a carbon filter should be replaced Unfortunately unknown factors such as concentration levels fresh air intake volume temperature and humidity prevent e...

Page 5: ...ipped with a Ground Fault Circuit Interrupt GFCI device A GFCI is an electrical safety device that will trip the circuit and stop the flow of electricity if leakage of current is detected Important Note The GFCI on this unit s control panel only detects leakage of current from the unit or an electrical device plugged into the GFCI This unit should be plugged into a GFCI receptacle at the power sou...

Page 6: ... risk of fire or electrical shock do not use this unit with any solid state speed control device Do not use in a cooking area Warning Do not position the unit so that it is difficult to operate the disconnecting device The disconnecting device is the power cord plug Caution This unit is designed for indoor use only Warning This unit is equipped with an automatic restart motorized impeller that wil...

Page 7: ... 6 GFCI Receptacle Electrical safety device that will trip and stop the flow of electricity if leakage of current is detected from the unit or an electrical device plugged into the GFCI receptacle The PRED750 PRED750EC can supply a total of 8 amps of electrical power for additional equipment that is connected to the GFCI receptacle Do not exceed this 8 amp limit Note If the equipment connected to ...

Page 8: ...e pressure compared to adjacent spaces so any air leakage will be an outflow of clean air and not inflow of contaminated air This pressure differential can be established by a placing the unit inside the containment area and using it to pull air into the area by attaching flex duct between the inlet collar and a location outside of the containment area b placing the unit outside of containment are...

Page 9: ... filters can be changed while in the stacked configuration It is not recommended to stack more than 3 units high due to safety as well as the compounding weight of the units STORAGE AND TRANSPORT OF THE UNIT TRANSPORTING THE UNIT The PREDATOR Portable Air Scrubber should be transported in its normal position resting on its rubber feet If extremely poor road conditions exist or excessive shock and ...

Page 10: ... this manual Filters can be changed earlier if desired to maintain a minimum required flow rate The unit should be cleaned with a damp cloth or a water based cleaner sanitizer as needed Do not use harsh chemicals solvents or detergents to clean the unit Warning Keep electrical components dry as their exposure to liquids poses a safety hazard and can damage components Test the GFCI located on the u...

Page 11: ... not reusable therefore do not attempt to clean and reuse them Caution Abatement Technologies PREDATOR Portable Air Scrubber units are designed to meet or exceed standards for high efficiency air filtration equipment Use only Abatement Technologies parts including replacement filters Use of non Abatement Technologies parts and filters voids the product warranty and all performance claims Warning T...

Page 12: ...he HEPA filter is held into place by two metal brackets Remove the two screws from each bracket and then remove the HEPA filter from the machine 5 Insert the new HEPA filter with the pleats oriented vertically and the air flow directional arrow on the filter pointing towards the control panel the gasketed side of the HEPA filter will be against the internal wall Note The HEPA filter is delicate an...

Page 13: ...0 hours of protection against UV deterioration Transportability Heavy duty flip up style transport handle Stackability Units are stackable and can stack up to 3 units high Pre filter access Hinged no tools pre filter access door with turn and latch closure and neoprene gasket First stage pre filter 1 deep coarse particulate pre filter Part Number F621 Second stage pre filter 2 deep pleated particu...

Page 14: ...gth of flex duct or eliminate restrictions Remove carbon filter from polybag Note If the unit does not start or malfunctions after carefully following the TROUBLESHOOTING GUIDE call Abatement Technologies service department at 800 634 9091 U S or 905 871 4720 Canada for assistance COMPONENT REPLACEMENT Warning To reduce the risk of fire electrical shock or personal injury always turn the unit OFF ...

Page 15: ...fications shall be held for Purchaser s shipping instructions which instructionsPurchasershall furnishpromptlyuponrequest ATI sliabilityshallinnoeventextend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly or indirectly arising from the use of the g...

Page 16: ...15 ...

Page 17: ...16 ...

Page 18: ...17 ...

Page 19: ...TCH13 CAM LATCH 2 13 HARDWRE153 HINGE 2 14 HARDWRE137 SHORT RUBBER FOOT 2 15 HARDWRE138 LONG RUBBER FOOT 2 16 1753 CONTROL PANEL BOX 1 17 ELE164 CAPACITOR 1 18 CTRLPNL101 CONTROL PANEL ASSEMBLY 1 19 1754 CONTROL PANEL PLATE 1 20 H5015 SPEED CONTROLLER 1 21 H5016 SPEED CONTROL KNOB 1 22 LAMP08 AMBER LAMP 1 23 LAMP10 GREEN LAMP 1 24 ELE71 GFCI RECEPTACLE 1 25 ELE152 12 AMP CIRCUIT BREAKER 1 26 ELE22...

Page 20: ...19 ...

Page 21: ...20 ...

Reviews: