PRED750 / PRED750EC SPECIFICATIONS
FEATURE
SPECIFICATIONS
Net weight with filters:
35 lbs.
Shipping weight:
43 lbs.
Unit dimensions:
19.5"W x 25.5"L x 20.5"H
Shipping carton dimensions:
20"W x 29"L x 21.5"H
Electrical Rating:
110-120VAC, 50/60Hz, 12A
Power supply requirements:
Minimum 15 amp circuit
Normal operating amps:
1.9 amps or less (excludes any other devices connected to control
panel outlet)
Maximum control panel outlet
rating:
8 amps
Maximum number of identical
daisy chained units:
4 additional units, 5 units total (using only the cord supplied with
the units)
Integrated circuit breaker:
12 amps
Motorized impeller:
Motorized impeller with thermal overload protection, auto reset,
60Hz, single phase
Operating flow rate:
(with clean filters)
Variable speed , air flow range from 200CFM to 750CFM.
Operational sound level:
65 dBA on max speed, reading taken at 5'.
Operating ambient temperature
range:
34
⁰F to 104⁰F
Cabinet:
Rotational-molded high density polyethylene cabinet. Contains
EPA registered additive for inhibiting microbial growth and UV-8
additive rated for 8,000 hours of protection against UV
deterioration.
Transportability:
Heavy duty flip-up style transport handle
Stackability:
Units are stackable and can stack up to 3 units high.
Pre-filter access:
Hinged "no tools" pre-filter access door with turn and latch closure
and neoprene gasket.
First stage pre-filter:
1" deep coarse particulate pre-filter (Part Number F621).
Second stage pre-filter:
2" deep pleated particulate pre-filter (Part Number H502).
Alternate second stage pre-filter:
2" deep high capacity carbon filter for odors (Part Number
VL1002).
HEPA filter:
HEPA mini-pleat filter with continuous seamless gasket, tested and
certified to an efficiency of 99.97% or higher against 0.3 micron
size particles (Part Number H161606-99).
Inlet & Outlet
Integrated 10" nominal diameter inlet and outlet.
Note: Specifications subject to change without notice.
Note: Airflow rating estimates are based on factory and independent testing at 120VAC, 60Hz with an air
straightener and a traverse of readings taken with a computing vane-anemometer. Actual results may vary for
various reasons, including motor and blower and HEPA filter tolerances. Factors such as filter loading, reduced
voltage to the motor, and inlet and outlet ducting will reduce airflow. Use the ratings as a general guideline
only.