Note
Action
xx1800002496
Remove the timing belt from its groove on the
motor.
11
Disconnecting the connectors at the division point
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800002497
Disconnect the connectors.
•
J2.FB3,4,5,6
•
J2.MP3,4,5/6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
2
xx1800002498
Snap loose and remove the female head of the
connectors from the connector plate.
3
Continues on next page
116
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the upper cable package
Continued