Note
Action
xx1800003002
Remove the cable bracket.
2
Disconnecting the axis-3 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800003003
Remove the lower arm support cover.
2
xx1800003004
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate, as shown in following step.
3
Continues on next page
124
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the upper cable package
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 588: ...This page is intentionally left blank ...
Page 610: ...This page is intentionally left blank ...
Page 614: ......
Page 615: ......