Putting the robot on its side
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
The IRB 1100 robot weighs 21.1 kg and can be
lifted by one person.
2
WARNING
The robot is likely to be mechanically unstable if
not secured to the foundation.
3
xx1800003033
Loosen the robot from the foundation by removing
the foundation attachment screws and put the
robot on its side.
4
Disconnecting the SMB cabling
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 46
2
Continues on next page
244
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued