Note
Action
Screw: M3x8 (1 pcs)
Apply a little Loctite 243 to the locking screw and
refit the locking screw.
Note
Make sure the locking screw header is parallel
with flange surface.
2
Tightening torque: 0.4 Nm
Valid for IRB 1100-4/0.475
xx1800003031
Note
If there is locking liquid residues on the screw or
screw hole, please clean it before refitting.
Remove residual locking liquid after refitting.
Valid for IRB 1100-4/0.58
xx1800003001
Plug screw: 3HAC064146-001
Valid for IRB 1100-4/0.58
3
Tightening torque: 2 Nm
xx1800003000
Refit the plug screw and washer on the extender
unit.
Continues on next page
Product manual - IRB 1100
343
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued