Securing the upper cable package to the housing
Note
Action
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (2 pcs)
Refit the cable bracket.
1
Tightening torque: 0.8 Nm
xx1800003013
Screw: M2.5x6 12.9 Gleitmo
603+Geomet 500 (2 pcs)
Tightening torque: 0.6 Nm
xx1800003014
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Continues on next page
344
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued