Note
Action
xx1800002950
Access the connector FB5 from the process hub
and disconnect the connector.
2
xx1800002993
Disconnect the connector.
•
MP5
3
Removing the axis-5 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800003290
Loosen the screws and move the motor slightly
to slacken the timing belt.
2
Continues on next page
Product manual - IRB 1100
443
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.5 Replacing the axis-5 motor
Continued