Note
Action
xx1800003291
Remove the screws and washers.
3
Carefully lift out the motor.
4
xx1800003292
Remove the timing belt from its groove on the
motor.
5
Refitting the motor
Use these procedures to refit the axis-5 motor.
Refitting the axis-5 motor
Note
Action
Check that:
•
all assembly surfaces are clean and without
damages
•
the motor is clean and undamaged.
1
Continues on next page
444
Product manual - IRB 1100
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.5 Replacing the axis-5 motor
Continued