Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
3
Disconnecting the SMB cabling
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 46
2
xx1800002467
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
3
xx1800002468
Disconnect the connectors.
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
Continues on next page
Product manual - IRB 1100
99
3HAC064992-001 Revision: C
© Copyright 20192020 ABB. All rights reserved.
4 Maintenance
4.6.1 Replacing the battery pack
Continued
Summary of Contents for IRB 1100
Page 1: ...ROBOTICS Product manual IRB 1100 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 588: ...This page is intentionally left blank ...
Page 610: ...This page is intentionally left blank ...
Page 614: ......
Page 615: ......