Removing the cable harness - upper end
Use these procedures to remove the upper end of the cable harness.
Preparations
Note
Action
xx1100000439
Jog the upper arm to a vertical position with
the wrist pointing at the floor.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot work-
ing area.
2
Remove all extra equipment fitted on the up-
per arm and wrist.
3
Continues on next page
Product manual - IRB 1520
163
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness - upper end
Continued