Removing motor cables and arm tube
Note
Action
xx1100000394
Remove the VK cover on the arm tube.
1
Disconnect the connectors of the axis 6 motor
through the hole for the VK cover.
Note
It is
not
needed to remove the motor.
2
Disconnect the connectors of the axis 5 mo-
tor.
Note
It is
not
needed to remove the motors.
3
Carefully pull out the cables of the axes 5 and
6 motors from the arm tube.
4
Remove the support ring and V-ring from the
arm tube and place them temporarily on the
cable harness spiral.
5