Note
Action
xx1100000420
Refit the cover with its attachment screws
except the one where the cable strap is fitted.
Note
The two lower attachment screws also holds
the bracket securing the cable harness to the
armhouse. Refit the bracket at the same time.
6
Refitting the cable harness spiral - part 1
Note
Action
Place the support ring and V-ring temporarily
on the cable harness spiral.
1
Fit two threaded bars (M8) in two of the attach-
ment holes diagonal to each other.
2
Lift the arm tube on to the threaded bars and
fit the nuts at the end of the bars.
3
xx1100000474
Lower the arm tube carefully and let it rest
on the nuts.
4
Continues on next page
172
Product manual - IRB 1520
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness - upper end
Continued