Note
Action
xx1100000349
Remove the armhouse cover.
5
See
Replacing the cable harness - upper
Disconnect all connectors inside the arm-
house and loosen the cabling from straps
and brackets.
6
xx1100000328
Remove the bracket holding the cable har-
ness to the armhouse and pull out the cable
harness.
7
Continues on next page
Product manual - IRB 1520
185
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
4 Repair
4.4.1 Replacing the complete upper arm, IRB 1520ID
Continued