Note
Action
xx0700000053
Disconnect the connectors R4.FB6 and
R4.MP6 to motor axis 6, through the hole for
the VK cover.
7
•
A: Connectors R4.FB6 & R4.MP6
xx0700000052
Remove the attachment screws securing the
wrist.
8
•
A: Hex socket head cap screw
M8x35 quality 8.8-A2F (3 pcs)
Remove the wrist with motor 6 from the upper
arm tube and put it on a work bench or simil-
ar.
CAUTION
Be careful when handling the wrist. Always
hold on the casting, do not hold on the wrist
cover. This can damage the sealing which
will cause oil leakage.
9
Refitting the wrist unit
Use this procedure to refit the complete wrist unit.
Note
Action
Move the wrist (with the axis 6 motor fitted)
to the mounting site.
1
Apply a string or similar to the cable harness
and run it out through the hole for the VK
cover.
2
Continues on next page