RMU 101
F
xx1300000330
Battery pack (3-pole battery contact)
B
Serial measurement board RMU 101
C
BU unit
D
Battery cable connector
E
Required equipment
Note
There are different variants of SMB units and batteries. The variant with the
3-pole battery contact has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Note
Art. no.
Equipment
See
.
Serial measurement unit
See
.
Battery pack
See
.
Gasket, base cover
Fitted to the push button unit
in order to align it correctly.
3HAC025815-001
Centering piece
Replace if damaged.
Content is defined in section
.
-
Standard toolkit
See chapter
.
-
Circuit diagram
Continues on next page
216
Product manual - IRB 1520
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the serial measurement unit
Continued
Summary of Contents for IRB 1520