Draining, axis 5-6 gearbox
Use this procedure to drain the axis 5-6 gearbox.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
WARNING
Handling gearbox oil involves several
safety risks, see
.
2
The capacity of the vessel must be sufficient
to take the complete amount of oil.
Position the robot as shown in the fig-
ure to the right:
•
upper arm: upwards for a stand-
ing robot.
•
axis 4: - 90º, to a position where
the oil plug (A) is faced down-
wards.
Note
The total amount of oil will not be
drained. There will remain approxim-
ately 20 ml in the wrist unit.
3
The figure shows IRB 1600 but the upper arm
position is the same for the IRB 1520.
xx0700000033
CAUTION
The gearbox can contain an
excess of
pressure
that can be hazardous. Open
the oil plug carefully in order to let out
the excess pressure.
4
Shown in figure
Location of oil plugs, axis 5-6
.
Remove the oil plug (A) and the ventil-
ation plug (B).
5
Continues on next page
Product manual - IRB 1520
123
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
3 Maintenance
3.4.5 Changing the oil in axes 5 and axis 5 and 6 gearboxes, IRB 1520ID
Continued
Summary of Contents for IRB 1520
Page 1: ...ROBOTICS Product manual IRB 1520 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 132: ...This page is intentionally left blank ...
Page 288: ...This page is intentionally left blank ...
Page 300: ...This page is intentionally left blank ...
Page 302: ...This page is intentionally left blank ...
Page 308: ......
Page 309: ......