WARNING
The robot installation is restricted to the mounting options given in following load
table(s).
Floor mounted
Max. load (emergency stop)
Endurance load (in operation)
Force
± 4300 N
± 1900 N
Force xy
1850 ±2350 N
1850 ±900 N
Force z
± 3900 Nm
± 1550 Nm
Torque xy
± 1200 Nm
± 390 Nm
Torque z
Suspended
Max. load (emergency stop)
Endurance load (in operation)
Force
± 4250 N
± 1900 N
Force xy
-1850 ±2350 N
- 1850 ±750 N
Force z
± 3900 Nm
± 1550 Nm
Torque xy
± 1200 Nm
± 390 Nm
Torque z
Requirements, foundation
The table shows the requirements for the foundation where the weight of the
installed robot is included:
Note
Value
Requirement
Flat foundations give better repeatability of the
resolver calibration compared to original settings
on delivery from ABB.
0.5 mm
Flatness of foundation
surface
The value for levelness aims at the circumstance
of the anchoring points in the robot base.
In order to compensate for an uneven surface,
the robot can be recalibrated during installation.
If resolver/encoder calibration is changed this
will influence the absolute accuracy.
15°
Maximum tilt
The value is recommended for optimal perform-
ance.
22 Hz
Note
It may affect the
manipulator life-
time to have a
lower resonance
frequency than
recommended.
Minimum resonance
frequency
Due to foundation stiffness, consider robot mass
including equipment.
i
For information about compensating for founda-
tion flexibility, see
Application manual - Control-
ler software IRC5
, section
Motion Process Mode
.
i
The minimum resonance frequency given should be interpreted as the frequency of the robot
mass/inertia, robot assumed stiff, when a foundation translational/torsional elasticity is added, i.e.,
the stiffness of the pedestal where the robot is mounted. The minimum resonance frequency should
not be interpreted as the resonance frequency of the building, floor etc. For example, if the equivalent
mass of the floor is very high, it will not affect robot movement, even if the frequency is well below
the stated frequency. The robot should be mounted as rigid as possibly to the floor.
Continues on next page
42
Product manual - IRB 1520
3HAC043435-001 Revision: L
© Copyright 2012-2020 ABB. All rights reserved.
2 Installation and commissioning
2.2.1 Pre-installation procedure
Continued
Summary of Contents for IRB 1520
Page 1: ...ROBOTICS Product manual IRB 1520 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 132: ...This page is intentionally left blank ...
Page 288: ...This page is intentionally left blank ...
Page 300: ...This page is intentionally left blank ...
Page 302: ...This page is intentionally left blank ...
Page 308: ......
Page 309: ......