Customer connections on upper arm with signal lamp
The figure shows the customer connections on the upper arm, including the optional
signal lamp that can be fitted to the arm house.
A
B
C
D
E
xx2000001660
R2.PROC1
A
Air M16x1.5
(24° cone sealing)
R2.ETHERNET
i
B
R2.CP or R2.CBUS
C
R2.CS or R2.CP/CS
D
Signal lamp
E
R3.H1 +, R3.H2 - (inside the arm house, not shown in figure)
-
i
Use a straight ethernet connector. Using an angled connector causes a collision risk with R2.CP,
R2.CBUS, R2.CS or R2.CP/CS.
Continues on next page
100
Product manual - IRB 4600
3HAC033453-001 Revision: Y
© Copyright 2009-2021 ABB. All rights reserved.
2 Installation and commissioning
2.8.2 Customer connection on robot
Continued