Note
Action
xx0900000017
Refit the
connectors
and
air hose
on the
bracket:
•
R1.CP/CS
•
R1.ETHERNET (if used)
•
R1.MP
Tip
Do not refit the
R1.SMB-connector
and
air
hose
at this stage. It will be easier to refit
these two when the bracket has been fitted
to the distance screws.
11
Connectors:
•
A: Earth cables
•
B: R1.SMB1-2
•
C: R1.SMB3-6
•
D: R2.SMB
•
E: R1.CP/CS
•
F: R1.MP
•
G: Air hose
•
H: Position of R1.ETHERNET (if
used)
•
J: R1.SMB
A
B
C
D
xx1200000887
A Base
B Distance screw
C Attachment screw
D Bracket
Secure the bracket on the distance screws.
12
Reconnect connectors on the brake release
unit:
•
X8
•
X9
•
X10
13
Continues on next page
Product manual - IRB 4600
219
3HAC033453-001 Revision: Y
© Copyright 2009-2021 ABB. All rights reserved.
4 Repair