Note
Action
A
B
C
xx0800000456
Remove the
base cover
.
CAUTION
Clean cover from metal residues before
opening.
Metal residues can cause shortage on the
boards which can result in hazardous fail-
ures.
4
Parts:
A Base
B Base cover
C Attachment screws M6x16 quality
8.8-A2F (6 pcs)
Take a picture or make notes of how the
robot cabling is positioned in regard to the
brake release board.
5
X9
X8
X10
xx1700000978
Disconnect
connectors X8, X9
and
X10
from
the brake release board.
6
Remove the
nuts
securing the brake release
board.
7
Remove the brake release board.
8
Refitting the brake release board
Use this procedure to refit the brake release board.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
1
Continues on next page
Product manual - IRB 4600
233
3HAC033453-001 Revision: Y
© Copyright 2009-2021 ABB. All rights reserved.
4 Repair
4.3.4 Replacing the brake release board
Continued
Summary of Contents for IRB 4600