Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
4
xx0800000335
Remove the
bracket
securing the cable
package to the tubular shaft unit by remov-
ing its attachment screws.
5
Parts:
•
A: Tubular shaft unit
•
B: Attachment screws M6x16 qual-
ity 8.8-A2F (2 pcs)
•
C: Bracket
Place the cable package in a way that it will
not be damaged in the continued removal
procedure.
6
How to remove motors is described in
section:
•
Remove motors axes 4, 5 and 6.
7
How to remove the wrist unit is detailed
in section:
•
Removal of wrist unit on page 265
Tip
If only the tubular shaft unit shall be re-
placed, it is a good idea to remove the
wrist
unit
at this stage.
8
CAUTION
The robot arm tube weighs 65 kg.
All lifting accessories used must be sized
accordingly.
9
Continues on next page
Product manual - IRB 4600
259
3HAC033453-001 Revision: Y
© Copyright 2009-2021 ABB. All rights reserved.
4 Repair
4.4.2 Replacing complete tubular shaft unit
Continued
Summary of Contents for IRB 4600
Page 1: ...ROBOTICS Product manual IRB 4600 ...
Page 8: ...This page is intentionally left blank ...
Page 334: ...This page is intentionally left blank ...
Page 368: ...This page is intentionally left blank ...
Page 376: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 392: ...This page is intentionally left blank ...
Page 398: ......
Page 399: ......