Refitting the wrist
Note
Action
xx1300000770
Lift the wrist and insert the guide pins into
the holes of the arm tube.
Tip
Leave a small opening between wrist and
arm tube. This will make it easier to run the
cable harness back into the wrist.
1
xx1300000769
Run the cabling into the wrist unit.
Be careful not to damage any part of the
cable harness.
2
xx1700001594
Slide the wrist into fitting position.
Make sure that the tubeshaft plate is placed
properly in the groove in the wrist.
3
Continues on next page
302
Product manual - IRB 6790
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the wrist
Continued