Note
Action
xx1900002085
•
Make sure that the gasket is undam-
aged on the cover. Replace com-
plete cover, if gasket is damaged.
•
Put washers in the holes of the gas-
ket.
•
Use attachment screws made of
stainless steel to fit the wrist cover.
2
Tightening torque: 10 Nm.
xx1300000772
Refit the wrist cover. Use this method not
to damage the cable harness:
1
Hold the cover tilted. See figure!
2
Catch any part of the cable harness
hanging down.
3
Lift the cover, still held tilted.
4
Move the upper part of the cover into
position.
5
Secure the cover with its attachment
screws.
3
Turn on the air pressure supply to the
overpressure system.
4
xx1700001593
Check the leak flow value on the flow
sensor and compare it to the initial value.
The value should be the same.
If the value is higher than the initial value,
fault trace according to
flow (overpressure unit) in the system on
page 128
5
Axis Calibration is described in
with Axis Calibration method on page 623
Re-calibrate the robot.
6
General calibration information is included
in section
.
Continues on next page
Product manual - IRB 6790
309
3HAC063331-001 Revision: B
© Copyright 2019 - 2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the wrist
Continued
Summary of Contents for IRB 6790
Page 1: ...ROBOTICS Product manual IRB 6790 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 38: ...This page is intentionally left blank ...
Page 164: ...This page is intentionally left blank ...
Page 612: ...This page is intentionally left blank ...
Page 638: ...This page is intentionally left blank ...
Page 644: ...This page is intentionally left blank ...
Page 658: ...This page is intentionally left blank ...
Page 660: ...This page is intentionally left blank ...
Page 667: ......